Studi Eksperimental Pengaruh Sudut Pipa Masuk (Driven Pipe) dan Diameter Katup Penghantar (Delivery Valve) terhadap Efisiensi Pompa Hidram 2 Inchi

Nurhayati Nurhayati, Muhamad Jafri, Noveryandy Muda

Abstract


It is undeniable that, the demand for water increases, but the availability of water relatively stable. Therefore, a technology has to be searched and developed to provide an adequate irrigation, efficient technology, efficient and economical, so that water availability and distribution can be managed well. One of the technological innovations, namely ram pump is a solution, because it does not require an electrical energy of the fuel. Beside that, this technology has a low operational cost and does not cause the economic burden for farmers. This experiment has done to know the efficiency of hydraulic ram pump by using driven pipe angle variations and delivery valve diameter. The hydraulic ramp pump used in this experiment has 2  inch inlet pipe (D) and 0.5 inch outlet pipe (d). After the experiment and analysis regression, resulting from that factors delivery valve diameter more influence the efficiency than the driven pipe angle.The highest efficiency of experiment result is driven pipe angle measure 8° and delivery valve diameter measure 1.5 inches, the efficiency is 43.18% at  D’ Aubussion efficiency and 37.61 % of Rankine efficiency

Keywords


hydraulic ram pump, driven pipe angle, delivery valve diameter, efficiency

Full Text:

PDF

References


A. M. Michael,. S. D. Kheper, 1997, Water Well Pump Engineering, McGraw Hill Publishing Compact Limited, New Delhi.

Budiyanto, 2009. Pengaruh Tinggi dan Diameter Inlet Terhadap Kapasitas Pompa Hidram Dengan Model Simulasi Program Delphi. Jurusan Teknik Mesin Fakultas Teknologi Industri Institut Teknologi Nasional Malang.

Hanafie, J,. de Longh, H. 1979. Teknologi Pompa Hidraolik Ram Buku Petunjuk Untuk Pembuatan dan Pemasangan. PTP-ITB Ganesha, Bandung.

Jafri, M. 2014. Rancangan Pompa Hidram. Jurusan Teknik Mesin Fakultas Teknik Universitas Nusa Cendana.

Sitompul, F.M,. Hazwi, M,. 2014. Pengujian Pengaruh Variasi Head Supply Dan Panjang Langkah Katup Limbah terhadap Unjuk Kerja Pompa Hidram. Jurusan Teknik Mesin, Universitas Sumatera Utara.

Sofwan M,. Siregar, I.H,. 2015. Pengaruh Ketinggian Terjunan dan Volume Tabung Udara Terhadap Kinerja Pompa Hidram. Jurusan Teknik Mesin Fakultas Teknik Universitas Negeri Surabaya.

Streeter, L,. Victor,. E Benjamin Wylie. 1985. Fluid Mechanics Eighth Edition. Erlangga. Jakarta.

Sularso,. Tahara, H,. 2004. Pompa dan Kompresor Pemilihan, Pemakaian dan Pemeliharaan . Pradya Paramita, Jakarta.

White, F. M., 1994, Fluid Mechanics, 3rd edition, McGraw-Hill, Inc., New York.